Title: | Thermodynamic analysis of multiple evacuated collector-driven organic Rankine cycle |
Authors: | Tiwari, Deepak |
Issue Date: | Jan-2024 |
Publisher: | International Journal of Exergy (Inder Science) |
Abstract: | In this study mathematical model of the organic Rankine cycle driven by multiple evacuated collectors is made in MATLAB 2018a. Results reflect that heat gain 2.726 × 105 W and output temperature 130°C for the collector were highest for collector no.6 at 13:00 hrs. Moreover, the highest system thermal efficiency 14.92%, and exergetic efficiency 56.99% were seen for collector no. 6 at 13:00 hrs. The major exergy loss of 42% was seen in the evaporator continued by the condenser of 32%, expander of 25%, and a minimal 2% in the pump. |
URI: | https://www.inderscienceonline.com/doi/abs/10.1504/IJEX.2023.135844 http://localhost:8080/xmlui/handle/123456789/578 |